PDED-20120-22N6

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) DeMux, 20 Channel 100 GHz 1561.42nm, 2m 250um bare fiber, Pass & Monitor

PDED-20120-22NK

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) DeMux, 20 Channel 100 GHz 1561.42nm, No Conn, Pass & bidirectional Monitor port

PDED-20140-22N6

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) DeMux, 20 Channel 100 GHz 1545.32nm, 2m 250um bare fiber, Pass & Monitor

PDED-20140-22NK

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) DeMux, 20 Channel 100 GHz 1545.32nm, No Conn, Pass & bidirectional Monitor port

PDED-40120-22NU

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) DeMux, 40 Channel 100 GHz 1561.42nm, No Conn, Bidirectional Monitor port

PDEM-20120-22N6

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) Mux, 20 Channel 100 GHz 1561.42nm, 2m 250um bare fiber, Pass & Monitor

PDEM-20140-22N6

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) Mux, 20 Channel 100 GHz 1545.32nm, 2m 250um bare fiber, Pass & Monitor

PDEM-C4121-195K

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) Mux, 4 Ch Custom 100 GHz, 1560.61, 1559.79, 1558.17, 1556.56, SC-APC, Pass & bidirectional Monitor port

PDEM-C4128-195K

Passive DWDM, Ruggedized Field Cassette E (85x75x8.5mm) Mux, 4 Ch Custom 100 GHz 1554.94, 1550.92, 1548.52, 1546.12, SC-APC, Pass & bidirectional Monitor port

PDFC-04120-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1561.42nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04120-1934

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channels 100 GHz spacing. Starting with Ch20 (1561.42nm), with Monitor option. 1m 900um leads LC/APC

PDFC-04120-1936

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channels 100 GHz spacing. Starting with Ch20 (1561.42nm), with Express and Monitor options. 1m 900um leads, LC/APC

PDFC-04120-1943

Passive DWDM, Field F Cassette (70x45x8.5mm),Combo Mux & DeMux, 4 Channel, 100 GHz spacing, starting channel 1561.42nm, 1m 900um buffer, LC-UPC, Pass Port

PDFC-04124-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1558.17nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04124-1943

Passive DWDM, Field F Cassette (70x45x8.5mm), Combo Mux & DeMux, 4 Channel, 100 GHz spacing, starting channel 1558.17nm, 1m 900um buffer, LC-UPC, Pass Port

PDFC-04128-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1554.94nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04128-1943

Passive DWDM, Field F Cassette (70x45x8.5mm), Combo Mux & DeMux, 4 Channel, 100 GHz spacing, starting channel 1554.94nm, 1m 900um buffer, LC-UPC, Pass Port

PDFC-04132-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1551.72nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04132-1943

Passive DWDM, Field F Cassette (70x45x8.5mm), Combo Mux & DeMux, 4 Channel, 100 GHz spacing, starting channel 1551.72nm, 1m 900um buffer, LC-UPC, Pass Port

PDFC-04136-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1548.52nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04136-1943

Passive DWDM, Field F Cassette (70x45x8.5mm), Combo Mux & DeMux, 4 Channel, 100 GHz spacing, starting channel 1548.52nm, 1m 900um buffer, LC-UPC, Pass Port

PDFC-04140-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1545.32nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04144-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1542.14nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04148-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1538.98nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04152-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1535.82nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFC-04156-1346

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Combo Mux & DeMux, 4 Channel 100 GHz 1532.68nm, 1.0m 2.0mm buffer, LC-UPC, Pass & Monitor

PDFD-058SS-19N4

Passive DWDM Field Cassette F (70x45x8.5mm) Demux 8ch \r\nBand Splitter with even splits. With 1 meter 900um fiber \r\nleads and 1% monitor tap. Rated for industrial temperature \r\noperation, -40c to +85c

PDFD-08120-1934

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Mux/DeMux, 8 Channels 100 GHz spacing. Starting with Ch20 (1561.42nm), with Monitor option. With 1m 900um fiber leads and LC/APC connectors

PDFD-08120-1936

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Mux/DeMux, 8 Channels 100 GHz spacing. Starting with Ch20 (1561.42nm), with Express and Monitor options. 1m 900um leads w LC/APC

PDFD-08120-1937

Passive DWDM, Ruggedized Field Cassette F (70x45x8.5mm) Mux/DeMux, 8 Channels 100 GHz spacing. Starting with Ch20 (1561.42nm), with Express, 1310 W/B & Monitor options. 1m 900um leads, LC/APC

PDFM-058SS-19N4

Passive DWDM Field Cassette F (70x45x8.5mm) Mux 8ch \r\nBand Splitter with even splits. With 1 meter 900um fiber \r\nleads and 1% monitor tap. Rated for industrial temperature \r\noperation, -40c to +85c

PDGR-01120-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 1 Channel with 100 GHz spacing, starting at 1561.42nm (ch20), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-01120-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 1 Channel with 100 GHz spacing, starting at 1561.42nm (ch20), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02120-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1561.42nm (ch20), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02120-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1561.42nm (ch20), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02122-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1559.79nm (ch22), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02122-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1559.79nm (ch22), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02124-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1558.17nm (ch24), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02124-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1558.17nm (ch24), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02126-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1556.55nm (ch26), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02126-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1556.55nm (ch26), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02128-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1554.94nm (ch28), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber\r\n

PDGR-02128-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1554.94nm (ch28), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02130-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1553.33nm (ch30), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02130-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1553.33nm (ch30), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02132-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1551.72nm (ch32), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02132-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1551.72nm (ch32), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02134-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1550.12nm (ch34), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber

PDGR-02134-155N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1550.12nm (ch34), and with 1.0m 900um colored fiber terminated in SC/APC connectors - Dual Fiber

PDGR-02136-153N-DUAL

Passive DWDM, Field Cassette G (95x70x10mm), Ring OADM, 2 Channels with 100 GHz spacing, starting at 1548.52nm (ch36), and with 1.0m 900um colored fiber terminated in LC/APC connectors - Dual Fiber